Technical Specifications
Instructions and Guidelines
An adequate thermal insulation and waterproofing package not only assures thermal ambient comfort, but also long term durability of the terracotta soffit inside the roof.
The waterproofing membrane protects the roof prior to the installation of the tiles and in case of accidental brakes, it assures the necessary waterproofing.
The use of the vapour barrier is indispensable for the correct functionality of the system
The tables indicate the suggested thickness of Stiferite’s panels based on
Suggested thickness STIFERITE Class B - Class S |
||
---|---|---|
Climate Zone |
DLgs 311/06 |
TAX deduction MD 65% |
A | 70 mm | 80 mm |
B | 70 mm | 80 mm |
C | 70 mm | 80 mm |
D | 80 mm | 100 mm |
E | 80 mm | 100 mm |
F | 80 mm | 100 mm |
Suggested thickness STIFERITE GT3 - GT4 - GT5 |
||
---|---|---|
Climate Zone |
DLgs 311/06 |
TAX deduction MD 65% |
A | 60 mm | 70 mm |
B | 60 mm | 70 mm |
C | 60 mm | 70 mm |
D | 70 mm | 90 mm |
E | 70 mm | 90 mm |
F | 80 mm | 100 mm |
Note: For different composition of structures or material, we suggest using the calculation program available online (see: Thermal transmittance and verifications of condensation with Glaser method)