Home | Contact us | Careers | Reserved Area |
Italian | Francais | Deutsch | Spanish
You are here: Building Insulation - Roofing - As a garden

Technical Specifications

  • Screen or vapour barrier
  • Lay down STIFERITE’s Class B panel
    (alternative: STIFERITE’s Class SSTIFERITE’s GT4)
  • Installation of waterproofing mantle made of two bituminous membranes minimum 4mm thick with reinforcement in TNT polyester in continuous strands. The second membrane must be made of an anti-root blend
  • Protective layer, drainage and filtering, small geo-composite mattress of ≥ 20mm thick.
  • Topsoil

Instructions and Guidelines
In order to guarantee a secure waterproofing seal and eventual maintenance to the finished package, it is of great importance to carefully design and  install a perfect package.

For the purpose of identifying areas of accidental breakage of the waterproofing mantle, it is recommended that the roof is subdivided using small relief pads.

Also see: the installation procedure

The tables indicate the suggested thickness of Stiferite’s panels based on

  • Climate Zones
  • Current legislative set limits of thermal transmittance
  • And the following composition of the structure:

 

Suggested thickness
STIFERITE Class B - STIFERITE Class S
Climate
Zone

DLgs 311/06

TAX deduction MD 65%
DM 26/10/2010

A 50 mm 70 mm
B 50 mm 70 mm
C 50 mm 70 mm
D 70 mm 80 mm
E 80 mm 90 mm
F 80 mm 90 mm

 

Suggested thickness
STIFERITE GT 4
Climate
Zone

DLgs 311/06

TAX deduction MD 65%
DM 26/10/2010

A 40 mm 60 mm
B 40 mm 60 mm
C 40 mm 60 mm
D 60 mm 70 mm
E 60 mm 80 mm
F 60 mm 80 mm

Note: For different composition of structures or material, we suggest using the calculation program available online (see: Thermal transmittance and verifications of condensation with Glaser method)

 

 

Tie point of Wall and Roof Garden