Technical Specifications
Instructions and Guidelines
Roof top terraces increase the amount of living space, but must ensure comfort and safety of the ambient below it.
In order to guarantee a secure waterproofing seal and eventual maintenance to the finished package, it is of great importance to carefully design and install a perfect package.
The tables indicate the suggested thickness of Stiferite’s panels based on
Suggested thickness STIFERITE Class B - STIFERITE Class S |
||
---|---|---|
Climate Zone |
DLgs 311/06 |
TAX deduction MD 65% |
A | 60 mm | 80 mm |
B | 60 mm | 80 mm |
C | 60 mm | 80 mm |
D | 80 mm | 90 mm |
E | 80 mm | 100 mm |
F | 80 mm | 100 mm |
Suggested thickness STIFERITE GT 4 |
||
---|---|---|
Climate Zone |
DLgs 311/06 |
TAX deduction MD 65% |
A | 50 mm | 60 mm |
B | 50 mm | 60 mm |
C | 50 mm | 60 mm |
D | 60 mm | 80 mm |
E | 60 mm | 90 mm |
F | 60 mm | 90 mm |
Note: For different composition of structures or material, we suggest using the calculation program available online (see: Thermal transmittance and verifications of condensation with Glaser method)