Home | Contact us | Careers | Reserved Area |
Italian | Francais | Deutsch | Spanish
You are here: Building Insulation - Walls - ETICSystems

Technical Specifications

  • Installation of insulation panel STIFERITE Class SK using pre-mixed plaster adhesive and nylon anchors.
  • Spread a layer of reinforcement plaster as a base coat on the panel, which will then serve as support of the fibre glass mesh.
  • Spread a layer of plaster over the fibre glass mesh.
  • Render finishing coat.

Instructions and Guidelines
Due to its’ excellent dimensional stability in  temperatures ranging from -40°C to  +110°C, STIFERITE Class SK panels in polyiso foam are ideal when used together with all finishing (render) elements in an ETICSystem.

The spreading method of the plaster adhesive varies based on the flatness of the wall being insulated.

Proceed to the next working phase only after the previous layer has completely dried.

Also see: the installation procedure

The tables indicate the suggested thickness of Stiferite’s panels based on

  • Climate Zones
  • Current legislative set limits of thermal transmittance
  • And the following composition of the structure:


Suggested thickness
STIFERITE Class SK
Climate
Zone

DLgs 311/06

TAX deduction MD 65%
DM 26/10/2010

A 20 mm 30 mm
B 40 mm 45 mm
C 40 mm 60 mm
D 60 mm 80 mm
E 60 mm 80 mm
F 60 mm 80 mm

Note: For different composition of structures or material, we suggest using the calculation program available online (see: Thermal transmittance and verifications of condensation with Glaser method)

 

 