Technical Specifications
Instructions and Guidelines
When the pitch is less than 20-25% use a bituminous membrane on top of the multi-layer wood support
The ventilation laths must be minimum 5cm in height and the distance between them at least 50/60 cm.
The tables indicate the suggested thickness of Stiferite’s panels based on
Suggested thickness STIFERITE Isoventilato |
||
---|---|---|
Climate Zone |
DLgs 311/06 |
TAX deduction MD 65% |
A | 60 mm | 70 mm |
B | 60 mm | 70 mm |
C | 60 mm | 70 mm |
D | 70 mm | 90 mm |
E | 80 mm | 100 mm |
F | 80 mm | 100 mm |
Note: For different composition of structures or material, we suggest using the calculation program available online (see: Thermal transmittance and verifications of condensation with Glaser method)